<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>solar inverter/charger &#8211; Afriwatt Engineering</title>
	<atom:link href="https://afriwatt.co.ke/product-tag/solar-inverter-charger/feed/" rel="self" type="application/rss+xml" />
	<link>https://afriwatt.co.ke</link>
	<description></description>
	<lastBuildDate>Fri, 07 Apr 2023 20:59:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://afriwatt.co.ke/wp-content/uploads/2023/02/cropped-Afriwatt-site-icon-1-1-32x32.png</url>
	<title>solar inverter/charger &#8211; Afriwatt Engineering</title>
	<link>https://afriwatt.co.ke</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>10KVA Pure Sine Wave Inverter With 120A MPPT Charger</title>
		<link>https://afriwatt.co.ke/product/10kva-pure-sine-wave-inverter-with-120a-mppt-charger/</link>
					<comments>https://afriwatt.co.ke/product/10kva-pure-sine-wave-inverter-with-120a-mppt-charger/#respond</comments>
		
		<dc:creator><![CDATA[Rhyl Kiio]]></dc:creator>
		<pubDate>Fri, 07 Apr 2023 20:59:03 +0000</pubDate>
				<guid isPermaLink="false">https://afriwatt1.tazamali.com/?post_type=product&#038;p=1977</guid>

					<description><![CDATA[10KVA 48V Low-Frequency Solar Inverter With 120A MPPT Solar Inverter, Long Lifespan, Digital Screen and Stronger Protection

<strong><span style="box-sizing: content-box; margin: 0px; padding: 0px; border: 0px; font-style: inherit; font-weight: inherit; line-height: 24px; font-family: Arial, sans-serif; vertical-align: baseline;">Features</span></strong>

<span style="font-size: 18px;">Bypass charging function,AC charge available when the unit off</span>

<span style="font-size: 18px;">90-280V AC Widely input voltage</span>

<span style="font-size: 18px;">Grid electricity and battery power priority is optional.</span>

<span style="font-size: 18px;">Higher charge current and adjustable</span>

<span style="font-size: 18px;">Communicate with our MPPT charge controller.</span>

<span style="font-size: 18px;">Intelligent protection, high class of security.</span>]]></description>
										<content:encoded><![CDATA[<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="et2" width="108" height="73">Model</td>
<td class="et3" colspan="3" width="435">IVPM10048</td>
</tr>
<tr>
<td class="et5" width="108" height="63">DC Input Voltage</td>
<td class="et6" colspan="3" width="435">48V</td>
</tr>
<tr>
<td class="et5" width="108" height="123">Rated output power(VA)</td>
<td class="et6" colspan="3" width="435">10000VA  8000W</td>
</tr>
<tr>
<td class="et5" width="108" height="93">Rated output power(W)</td>
<td class="et6" colspan="3" width="435">8000W</td>
</tr>
<tr>
<td class="et5" width="108" height="93">Input voltage waveform</td>
<td class="et6" colspan="3" width="435">Sine(public facility or generator)</td>
</tr>
<tr>
<td class="et5" width="108" height="93">Rated input voltage</td>
<td class="et6" colspan="3" width="435">220vac</td>
</tr>
<tr>
<td class="et7" width="108" height="93">G<span class="font5">rid low voltage</span></td>
<td class="et6" colspan="3" width="435">90Vac<span class="font1">±</span><span class="font2">7Vac  </span></td>
</tr>
<tr>
<td class="et7" width="108" height="153">G<span class="font5">rid low voltagerecovery voltage</span></td>
<td class="et8" colspan="3" width="435">100Vac<span class="font1">±</span><span class="font2">7Vac  </span></td>
</tr>
<tr>
<td class="et7" width="108" height="93">G<span class="font5">rid high voltage</span></td>
<td class="et8" colspan="3" width="435">280Vac<span class="font1">±</span><span class="font2">7Vac</span></td>
</tr>
<tr>
<td class="et7" width="108" height="153">G<span class="font5">rid high voltage recovery voltage</span></td>
<td class="et8" colspan="3" width="435">270Vac<span class="font1">±</span><span class="font2">7Vac</span><span class="font5"> </span></td>
</tr>
<tr>
<td class="et7" width="108" height="93">M<span class="font5">ax input voltage</span></td>
<td class="et6" colspan="3" width="435">280Vrms</td>
</tr>
<tr>
<td class="et5" width="108" height="123">Rated input frequency</td>
<td class="et6" colspan="3" width="435">50Hz/60Hz</td>
</tr>
<tr>
<td class="et7" width="108" height="93">G<span class="font5">rid underfrequency</span></td>
<td class="et6" colspan="3" width="435">40<span class="font1">±</span><span class="font2">1Hz</span></td>
</tr>
<tr>
<td class="et7" width="108" height="123">G<span class="font5">rid underfrequency recovery</span></td>
<td class="et6" colspan="3" width="435">42<span class="font1">±</span><span class="font2">1Hz</span></td>
</tr>
<tr>
<td class="et7" width="108" height="93">G<span class="font5">rid overfrequency</span></td>
<td class="et6" colspan="3" width="435">65<span class="font1">±</span><span class="font2">1Hz</span></td>
</tr>
<tr>
<td class="et7" width="108" height="123">G<span class="font5">rid </span><span class="font3">over</span><span class="font5">frequency recovery</span></td>
<td class="et6" colspan="3" width="435">43<span class="font1">±</span><span class="font2">1Hz</span></td>
</tr>
<tr>
<td class="et7" width="108" height="63">O<span class="font5">utput waveform</span></td>
<td class="et6" colspan="3" width="435">Synchronize with input voltage</td>
</tr>
<tr>
<td class="et7" width="108" height="123">O<span class="font5">verload protection</span></td>
<td class="et6" colspan="3" width="435">Air switch protection</td>
</tr>
<tr>
<td class="et7" width="108" height="153">O<span class="font5">utput short circuit protection</span></td>
<td class="et6" colspan="3" width="435">Air switch protection</td>
</tr>
<tr>
<td class="et7" width="108" height="63">E<span class="font5">fficiency(grid)</span></td>
<td class="et9" colspan="3" width="435">≥95%</td>
</tr>
<tr>
<td class="et5" width="108" height="123">Switching time(AC TO DC)</td>
<td class="et6" colspan="3" width="435">15ms Typical value</td>
</tr>
<tr>
<td class="et5" width="108" height="123">Switching time(DC TO AC)</td>
<td class="et6" colspan="3" width="435">15ms Typical value/30ms special value</td>
</tr>
<tr>
<td class="et7" width="108" height="93">T<span class="font5">hrough battery free</span></td>
<td class="et6" colspan="3" width="435">NO</td>
</tr>
<tr>
<td class="et5" width="108" height="93">Grid max bypass current</td>
<td class="et6" colspan="3" width="435">60A</td>
</tr>
<tr>
<td class="et10" colspan="4" width="543" height="38">Charging parameter</td>
</tr>
<tr>
<td class="et5" width="108" height="93">Rated input voltage</td>
<td class="et11" colspan="3" width="435">220Vac</td>
</tr>
<tr>
<td class="et7" width="108" height="93">I<span class="font5">nput voltage range</span></td>
<td class="et6" colspan="3" width="435">90-280Vac</td>
</tr>
<tr>
<td class="et7" width="108" height="93">R<span class="font5">ated voltage output</span></td>
<td class="et6" colspan="3" width="435">Depending on batty type</td>
</tr>
<tr>
<td class="et7" width="108" height="93">M<span class="font5">ax charging current</span></td>
<td class="et6" colspan="3" width="435">80A</td>
</tr>
<tr>
<td class="et5" width="108" height="153">Adjustable charging current range</td>
<td class="et6" colspan="3" width="435">0-80A</td>
</tr>
<tr>
<td class="et5" width="108" height="123">Initial voltage of the battery</td>
<td class="et6" colspan="3" width="435">Breaker</td>
</tr>
<tr>
<td class="et7" width="108" height="123">C<span class="font5">harging short circuit current</span></td>
<td class="et6" colspan="3" width="435">63A</td>
</tr>
<tr>
<td class="et7" width="108" height="63">B<span class="font5">reaker size</span></td>
<td class="et12" colspan="3" width="435">D<span class="font5">ependent on battery type or self-defined</span></td>
</tr>
<tr>
<td class="et7" width="108" height="123">O<span class="font5">vercharge protection</span></td>
<td class="et6" colspan="3" width="435">Yes</td>
</tr>
<tr>
<td class="et13" colspan="4" width="543" height="61">MPPT Charging&amp;Grid Charging(MPPT built-in controller is option)</td>
</tr>
<tr>
<td class="et7" width="108" height="123">M<span class="font5">ax PV open circuit voltage</span></td>
<td class="et14" colspan="3" width="435">195V</td>
</tr>
<tr>
<td class="et5" width="108" height="123">PV voltage working range</td>
<td class="et16" colspan="3" width="435">60-195VDC</td>
</tr>
<tr>
<td class="et7" width="108" height="93">M<span class="font5">ax input power</span></td>
<td class="et16" colspan="3" width="435">6600W</td>
</tr>
<tr>
<td class="et7" width="108" height="123">M<span class="font5">ax mains charging current</span></td>
<td class="et16" colspan="3" width="435">120A</td>
</tr>
<tr>
<td class="et7" width="108" height="183">M<span class="font5">ax charging current(mains+solar energy)</span></td>
<td class="et16" colspan="3" width="435">200A</td>